-40%
8CH Thermocouple Pt100 Cu50 V/A Thermometer Data Logger Recorder 7'' TFT LCD
$ 422.4
- Description
- Size Guide
Description
Note: we'll ship this item viaexpress mail service
to USA, Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea,Thailand, Malaysia, Indonesia, Philippine, Singapore.
Clients from other countries pls contact with us in advance to confirm the different shipping charges before you order.
Standard Accessories
:
NAPUI-1 temperature module with 8CH thermocouples, power cord(AU, US, UK and Euro plug), software, PDF manual,
Optional accessories:
Li-batteries, other temperature modules with thermocouples.
Model
130T
PC
interface
Equipped with Ethernet (100 Base-TX) interface
OS
Must be installed in advance the following any version of the operating system: Windows vista Ultimate, Windows Vista Business, Windows Vista Home Premium, Windows Vista Home Basic, Windows XP Professional, Windows XP Home Edition, Windows2000 Professional.
Language support
English/simplified Chinese/traditional Chinese
processor
Pentium
Ⅲ
equivalent to more than 1 GHz clock frequency above (1.7 GHz clock frequency Suggestions above)
Memory capacity
More than 256MB (suggestions for 512MB above), using the Windows Vista is more than 512MB (suggestions for 1GB above)
Installation required memory capacity
100MB
display screen
High Color(16bit) above, Resolution 1024 * 768 pixels above, display Color High Color (16 bit) above, 7 inches
printer
300 dpi above
When using Excel transmission function
Install the Excel above 97 version
When using HTTP server (Web server) function
Install the Internet Explorer5.5 (Service Pack2) above version
When using FTP server
Install a FTP terminal function application software
Model
NAPUI130T high precision input measuring unit
I
nput methods
Floating don't balance between input CH, CH-other units, power port FG insulation resistance measurement between port, the insulation between for CH
Number
of
frequency band
input 8CH (support max. 64CH, need pay extra for them)
Measurement period
The fastest sampling inspection period 1 s (1 ch, AD total time 1 s) to 9999 s
Synchronize th
e measuring unit
±100ps bellow
AD
transform way
ΔΣ
way
AD
Resolution
16bits
AD
cumulative time
2ms, 16.7ms, 20ms
I
nput
types
Voltage, ±10V, ±5V, ±1V, ±0.5V, ±0.1V, 1-5V thermocouple K, J, E, R, S, B and N, temperature measuring the resistance body Pt100, Cu503 zone current 1 mA logic voltage regulation, logical contact
Benchmark contact compensation
Can internal/external switch (points respectively, external set band set to 0
C
)
Benchmark contact compensation accuracy
±0.5C
(
23C±5C, the input port when temperature balance)
Maximum input voltage (rated)
±60V
Input resistance
Thermocouple, voltage 1 v the following, logic contacts
100 M Ω above
Voltage 1-5 V. 5 V level or above, logic voltage
About 1 M Ω
Withstand voltage
Measured input port-FG port, and between box
1500VAC (50/60 Hz)
Measured input port, and a power between port
Measured input ports between each other (other between units)
Measured input ports between each other (the same units)
600VAC (50/60Hz)
Input signal source resistance
Voltage: thermocouple
2 K Ω
below
temperature
r
esistance body
1 line 10
Ω
the following (3 line are equal)
temperature
r
esistance body
Thermocouple level (detection current: about 64 pA), 1-5 V range (detection voltage: less than 0.58 V)
Burn out test cycle
According to measurement cycle for testing
Measurement range
Input type
Can measure range
Measurement accuracy (AD total time 16.7 ms, 20 ms)
Display resolution
±10V
-11.000V to +11.000V
±0.5%of rdg±2 digit
1mV
±5V
-5.500V to +5.500V
±0.5%of rdg±2 digit
1mV
±1V
-1.1000V to +1.1000V
±0.5%of rdg±2 digit
0.1mV
±500mV
-550.0m to +550.0mV
±0.5%of rdg±2 digit
0.1mV
±100mV
-110.00mV to +110.00mV
±0.5%of rdg±2 digit
0.01mV
1-5V
+0.800V to +5.200V
±0.5%of rdg±2 digit
1mV
4-20mA
+0.38mA to +21.00mA
±0.5%of rdg±2 digit
0.01mA
K
-100°C to +1372°C
±0.5%of rdg±0.6°C
0.05°C
-200°C to -100°C
±0.5%of rdg±0.9°C
J
-100°C to +1200°C
±0.5%of rdg±0.6°C
0.05°C
-200°C to -100°C
±0.5%of rdg±0.8°C
E
-100°C to +1000°C
±0.5%of rdg±0.6°C
0.05°C
-200°C to -100°C
±0.5%of rdg±0.8°C
T
-100°C to +400°C
±0.5%of rdg±0.5°C
0.01°C
-200°C to -100°C
±0.5%of rdg±0.8°C
N
0°C to +1300°C
±0.5%of rdg±0.6°C
0.05°C
W
+1500°C to +2315°C
±0.5%of rdg±1.1°C
0.05°C
0°C to +1500°C
±0.5%of rdg±0.8°C
R
+300°C to +1768°C
±0.5%of rdg±0.8°C
0.05°C
0°C to +300°C
±0.5%of rdg±1.6°C
S
+300°C to +1768°C
±0.5%of rdg±0.9°C
0.05°C
0°C to +300°C
±0.5%of rdg±1.6°C
B
+400°C to +600°C
±0.5%of rdg±1.7°C
0.05°C
+600°C to +1820°C
±0.5%of rdg±1.0°C
Pt100
-200°C to +660°C
±0.5%of rdg±0.3°C
0.02°C
CU50
-50°C to +150°C
±0.5%of rdg±0.3°C
0.02°C
Preheating time
More than 30 minutes
Ability to adapt to the environment
Surrounding temperature
0C to +50C
surrounding
humidity
20% to 85%RH
(
No condensation
)
Weight
About 2.8Kg
Data
save
Built-in 64M flash memory; Support U disk(U disk is not included in the package)
As long as the U disk insert TP series recorder, can set the start time and end time to save data to a U disk. Thus, without the need to replace the chart recorder paper operation and traditional data recorder trouble button operation.
Flexible operation
The instrument can be flexible to your company to provide the change of the design service, measuring unit not only can be removed and installation of input and output module, and its structure can tear open next port sets, can reduce Settings, wiring, time, support hot swaps (both in power-on state directly plug measuring unit module), operate up is very convenient.